I actually misspoke, the minimum polling rate is once every 64 seconds (max is 512 times a second). The brownout detector is clocked from a 1024 Hz clock, prescaled by a factor from 2 to 65536. I do wonder though if my momentary re-enabling when I wake up will trigger the check…